UN ECE R10 shows the EMC tests which are applicable for Electronic Sub Assemblies(ESAs) and Vehicles. Some of applicable EMC tests according to Revision 6 of the regulation are listed below. To reach full list, click on Download.

APPLIED FOR THE PRODUCT(S)TEST TYPETEST NAMEREFERENCE STANDARD(S)RELATED ANNEX AND PAGES OF UN ECE R10 REV6
Vehicles with configurations of the vehicle:
(a) Other than “REESS charging mode coupled to the power grid”
(b) “REESS charging mode coupled to the power grid”
EmissionMeasurement of radiated broadband electromagnetic emissions from vehiclesCISPR 12Annex 4(p.61-73)
ESAs:
(a) Other ESAs than involved in “REESS charging mode coupled to the power grid”.
(b) ESAs involved in “REESS charging mode coupled to the power grid”
EmissionMeasurement of radiated broadband electromagnetic emissions from electrical/electronic sub-assemblies (ESAs)CISPR 25
CISPR 12
Annex 7(p.92-97)
ESAs other than those involved in “REESS charging mode coupled to the power grid”EmissionMeasurement of radiated narrowband electromagnetic emissions from electrical/electronic
sub-assemblies
CISPR 25
CISPR 12
CISPR 16-1-4
Annex 8(p.98-99)
ESAs:
(a) Other ESAs than involved in “REESS charging mode coupled to the power grid”
(b) ESAs involved in “REESS charging mode coupled to the power grid”
ImmunityTesting for immunity of electrical/electronic subassemblies to electromagnetic radiationISO 11452-2
ISO 11452-3
ISO 11452-4
ISO 11452-5
ISO 11452-1
Annex 9(p.100-112)
ESAs in configuration “REESS charging mode coupled to the power grid”.ImmunityTesting for immunity of an ESA to Electrical Fast Transient/Burst disturbances conducted along AC and DC power linesIEC 61000-4-4Annex 21(p.153-155)

EMC Tests applied for Vehicles according to UN ECE Regulation 10 Revision 6

UN ECE R10 differentiates vehicles according to its features and configurations. There are two main features: REESS charging mode coupling and immunity related functions. These two features define the vehicle category and applicable EMC tests.

Vehicle Category

Vehicle Configuration Description

1

Vehicles in configurations other than REESS charging mode coupled to the power grid

* vehicles without immunity related functions

2

Vehicles in configuration “REESS charging mode coupled to the power grid”

* vehicles without immunity related functions

3

Vehicles in configurations other than REESS charging mode coupled to the power grid

* vehicles with immunity related functions

4

Vehicles in configuration “REESS charging mode coupled to the power grid”

* vehicles with immunity related functions

 

Test / EUT Vehicles in configurations
other than REESS charging mode
coupled to the power grid
* vehicles without immunity related functions
Vehicles in configuration
“REESS charging mode coupled to the power grid”
* vehicles without immunity related functions
Vehicles in configurations
other than REESS charging mode
coupled to the power grid
* vehicles with immunity related functions
Vehicles in configuration
“REESS charging mode coupled to the power grid”
* vehicles with immunity related functions
Radiated Emissions (30MHz-1GHz)
Broadband (Peak, Quasi-Peak)
Test Site: ALSE or OTS
Required Required Required Required
Radiated Emissions (30MHz-1GHz)
Narrowband (Average)
Test Site: ALSE or OTS
Required Not Required Required Not Required
Radiated Immunity (20MHz-2GHz)
Absorber chamber test according to ISO 11451-2
Test Site: ALSE or OTS
Not Required Not Required Required Required
Conducted Emissions (0.15-30MHz)
for AC&DC power lines
Test Site: Shielded Enclosure,
ALSE or OATS
Not Required Required Not Required Required
Conducted Emissions (0.15-30MHz)
for wired network ports
Test Site: Shielded Enclosure,
ALSE or OATS
Not Required Required Not Required Required
Harmonics Emissions (AC power lines)
≤ 16 A per phase (IEC 61000-3-2)
> 16 A and ≤ 75 A per phase (IEC 61000-3-12)
Not Required Required Not Required Required
Voltage fluctuations and Flicker Emissions (AC power lines)
≤ 16 A per phase (IEC 61000-3-3)
> 16 A and ≤ 75 A per phase (IEC 61000-3-11)
Not Required Required Not Required Required
EFT/Burst Immunity (IEC 61000-4-4)
AC or DC power lines: ± 2 kV
Not Required Not Required Not Required Required
Surge Immunity (IEC 61000-4-5)
AC power lines: ± 2 kV
DC power lines: ± 0.5 kV
Not Required Not Required Not Required Required