UN ECE Regulation 10 requires EMC tests for Electronic Sub Assemblies (ESAs) used for automotive. According to UN ECE R10 revision 6, ESAs are grouped into two:
- ESAs in configuration other than ”REESS charging mode coupled to the power grid”
- ESAs in configuration “REESS charging mode coupled to the power grid”
On this post we will list all EMC tests for ESAs in configuration ”REESS charging mode coupled to the power grid”
Test under UN ECE R10 Rev.6 | ESAs in configuration “REESS charging mode coupled to the power grid” |
Test Site |
Radiated Emissions (30MHz-1GHz) | Required | ALSE or OATS |
Radiated Immunity (20-400MHz) Bulk current injection testing according to ISO 11452-4 |
Required | Shielded Enclosure |
Radiated Immunity (400MHz-2GHz) Absorber chamber test according to ISO 11452-2 |
Required | ALSE |
Transient Emissions (ISO 7637-2) 12V system: +75 V and -100V 24V system: +150 V and -450V |
Required | N/A |
Transient Immunity (ISO 7637-2) Pulse No: 1, 2a, 2b, 3a/3b |
Required | N/A |
Transient Immunity (ISO 7637-2) Pulse No: 4 |
Not Required | N/A |
Conducted Emissions (0.15-30MHz) | Required | Shielded Enclosure, ALSE or OATS |
Harmonics Emissions (AC power lines) ≤ 16 A per phase (IEC 61000-3-2) > 16 A and ≤ 75 A per phase (IEC 61000-3-12) |
Required | N/A |
Voltage fluctuations and Flicker Emissions (AC power lines) ≤ 16 A per phase (IEC 61000-3-3) > 16 A and ≤ 75 A per phase (IEC 61000-3-11) |
Required | N/A |
EFT/Burst Immunity (IEC 61000-4-4) AC or DC power lines: ± 2 kV |
Required | N/A |
Surge Immunity (IEC 61000-4-5) AC power lines: ± 2 kV DC power lines: ± 0.5 kV |
Required | N/A |
Required tests are for
EMC tests for ESAs in configuration other than ”REESS charging mode coupled to the power grid”
Do you need more information about ECE R10 Tests and Certification?
Download our ECE R10 Certification Guide and learn more about ECE R10 tests and certification. Guide covers for both ESAs and vehicles.
Recent Comments