Are you interested in EMC Tests of vehicles according to UN ECE R10?
We listed EMC test setup requirements for you.
On this page you will wind EMC test setup requirements for the EMC tests that is required for vehicles. In this guide we are listing the test setup requirements for EMC testing of vehicles according to UN ECE Regulation 10 Revision 6. Our reference document is UN ECE R10 and its latest version of Revision 6. This regulation is applicable from the UN ECE website and it is free to download. Please take into consideration of the features of the vehicle that will be tested and the revision of UN ECE R10.
What will you find on this guide? You will find these headings on the 19-page guide:
1. Vehicle Configurations
2. Charging Modes according to UN ECE R10
3. EMC Tests for Vehicles
4. EMC Test Setup Examples
5. Test Site Requirements for Radiated Emissions
6. Test Sites mentioned under UN ECE R10
7. Summary of EMC Tests for Vehicles according to UN ECE R10
This free guide issued by Testups for the automotive industry and it is regularly updated.
UN ECE R10 differentiates vehicles according to its features and configurations. There are two main features: REESS charging mode coupling and immunity related functions. These two features define the vehicle category and applicable EMC tests.
Vehicle Category | Vehicle Configuration Description |
1 |
Vehicles in configurations other than REESS charging mode coupled to the power grid * vehicles without immunity related functions |
2 |
Vehicles in configuration “REESS charging mode coupled to the power grid” * vehicles without immunity related functions |
3 |
Vehicles in configurations other than REESS charging mode coupled to the power grid * vehicles with immunity related functions |
4 |
Vehicles in configuration “REESS charging mode coupled to the power grid” * vehicles with immunity related functions |
We can derive three vehicle categories in terms of EMC tests listed under UN ECE Regulation 10:
* All Vehicle categories listed under the scope of UN ECE R10
* Vehicles with immunity related functions
* Vehicles with REESS charging mode
Test / EUT | Vehicles in configurations other than REESS charging mode coupled to the power grid * vehicles without immunity related functions |
Vehicles in configuration “REESS charging mode coupled to the power grid” * vehicles without immunity related functions |
Vehicles in configurations other than REESS charging mode coupled to the power grid * vehicles with immunity related functions |
Vehicles in configuration
“REESS charging mode coupled to the power grid” * vehicles with immunity related functions |
Radiated Emissions (30MHz-1GHz) Broadband (Peak, Quasi-Peak) Test Site: ALSE or OTS |
Required | Required | Required | Required |
Radiated Emissions (30MHz-1GHz) Narrowband (Average) Test Site: ALSE or OTS |
Required | Not Required | Required | Not Required |
Radiated Immunity (20MHz-2GHz) Absorber chamber test according to ISO 11451-2 Test Site: ALSE or OTS |
Not Required | Not Required | Required | Required |
Conducted Emissions (0.15-30MHz) for AC&DC power lines Test Site: Shielded Enclosure, ALSE or OATS |
Not Required | Required | Not Required | Required |
Conducted Emissions (0.15-30MHz) for wired network ports Test Site: Shielded Enclosure, ALSE or OATS |
Not Required | Required | Not Required | Required |
Harmonics Emissions (AC power lines) ≤ 16 A per phase (IEC 61000-3-2) > 16 A and ≤ 75 A per phase (IEC 61000-3-12) |
Not Required | Required | Not Required | Required |
Voltage fluctuations and Flicker Emissions (AC power lines) ≤ 16 A per phase (IEC 61000-3-3) > 16 A and ≤ 75 A per phase (IEC 61000-3-11) |
Not Required | Required | Not Required | Required |
EFT/Burst Immunity (IEC 61000-4-4) AC or DC power lines: ± 2 kV |
Not Required | Not Required | Not Required | Required |
Surge Immunity (IEC 61000-4-5) AC power lines: ± 2 kV DC power lines: ± 0.5 kV |
Not Required | Not Required | Not Required | Required |
Annex 12-Emission of Voltage changes, voltage fluctuations and flicker on AC power lines-Example Setup
Location
Testups Ireland Limited is a registered company with registration number 634977. Tax ID: 3570537IH
Registered address: 22 Northumberland Road, Ballsbridge, Dublin 4. D04 ED73 Ireland