HARMONICS AND FLICKER ANALYZER (IEC 61000-3-2 and IEC 61000-3-3 Test System)

Do you want to perform Harmonic Current Emissions test according to IEC/EN 61000-3-2? Or do you want to measure voltage changes, voltage fluctuations and flicker according to IEC/EN 61000-3-3? We are offering Harmonics & Flicker Analyzer that is fully compliant with the latest versions of IEC/EN 61000-3-2 and IEC/EN 61000-3-3. Fulfil your harmonics emissions, flicker and EMC requirements with standard compliant test systems including software. Perform harmonics emissions and flicker tests in house. We are delivering Harmonics and Flicker Analyzer test systems to your address in 6-8 weeks.
Contact us and get your quote:

IEC 61000-3-2 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which can be produced by equipment tested under specified conditions. This standard is applicable to electrical and electronic equipment having a rated input current up to and including 16 A per phase, and intended to be connected to public low-voltage distribution systems.

IEC 61000-3-3 is concerned with the limitation of voltage fluctuations and flicker impressed on the public low-voltage system. It specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and gives guidance on methods of assessment. This standard is applicable to electrical and electronic equipment having an input current equal to or less than 16 A per phase, intended to be connected to public low-voltage distribution systems of between 220 V and 250 V line to neutral at 50 Hz, and not subject to conditional connection.

Harmonics emissions and flicker emissions are measured with analyzers.

What we offer?

We are offering IEC/EN 61000-3-2 and IEC/EN 61000-3-3 compliant Harmonics and Flicker Analyzers. For accurate measurements, you will also need clean power source. Send us your harmonics and flicker analyzer requirements and get quote.

AC2000A Harmonics and Flicker Analyzer has a universal and single power supply input. You can supply the instrument either with 220V AC(50Hz) or 110V AC(60Hz). The switch on power supply input shall be set properly before using. 

AC2000A Harmonics and Flicker Analyzer has three EUT power supply versions (when ordering the unit please choos one of these):

1) 220V 50Hz with UK plug (this version is generally in stock)

2) 220V 50Hz with EU (Schkuo) plug (this version is generally in stock)

3) 115V 60Hz with US plug (this version is generally not in stock, it is manufactured after a purchase order)

IEC 61000-3-12 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which can be produced by equipment tested under specified conditions. This standard is applicable to electrical and electronic equipment having a rated input current between 16 A and 75 A per phase, and intended to be connected to public low-voltage distribution systems. For full compliance testing, Harmonics Analyzers are designed according to IEC/EN 61000-4-7 standard. 

IEC 61000-3-11 is concerned with the limitation of voltage fluctuations and flicker impressed on the public low-voltage system. It specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and gives guidance on methods of assessment. This standard is applicable to electrical and electronic equipment having an input current between 16 A and 75 A per phase, intended to be connected to public low-voltage distribution systems of between 220 V and 250 V line to neutral at 50 Hz, and not subject to conditional connection.

Harmonics emissions and flicker emissions are measured with analyzers.

What we offer?

We are offering IEC/EN 61000-3-12, IEC/EN 61000-3-11, IEC/EN 61000-4-7, IEC/EN 61000-4–15 compliant Harmonics and Flicker Analyzers. Send us your harmonics and flicker analyzer requirements and get quote.

Harmonics and Flicker Analyzer Test System we offer (For Sale)

Order Code Product Name Description
THFTS-01 Harmonics & Flicker Analyser

The AC2000A is a Harmonics and Flicker analyser that is fully compliant with the latest versions of IEC61000-3-2  and IEC61000-3-3

Datasheet

THFTS-02 Clean Power Source

A power source that provides up to 1kW of 50Hz mains supply that meets the THD requirements of IEC61000-3-2

Datasheet

Lead time: 2-3 weeks

Harmonics and Flicker Analyzer Test System we offer (For Rental)

Order Code Product Name Description
THFTS-01 Harmonics & Flicker Analyser

The AC2000A is a Harmonics and Flicker analyser that is fully compliant with the latest versions of IEC61000-3-2  and IEC61000-3-3

Datasheet

Lead time: 1-2 weeks. Rental services are only valid for these countries: United States, United Kingdom, Canada, Ireland, Hungary and all EU member states. 

Do you want to perform IEC/EN 61000-3-2, IEC/EN 61000-3-3, IEC/EN 61000-3-11 or IEC/EN 61000-3-12 tests in house?

Contact us and get quote from us for:

* IEC/EN 61000-3-2 and IEC 61000-3-3 compliant Harmonics and Flicker Analyzer

* Clean Power Source for IEC/EN 61000-3-3

* IEC/EN 61000-3-2, IEC 61000-3-3, IEC/EN 61000-3-12, IEC 61000-3-11 compliant Harmonics and Flicker Analyzer System

We are engineers, experts and consultants specialised in electrical product testing and certification.

With our team, laboratory and partner laboratories, we are providing testing and certification services for electrical products. We are partnering with testing laboratories located in USA, Ireland, United Kingdom, Germany, Hungary, Italy, Turkey, China, Brazil and South Africa. We are providing our services worldwide.

We are also collaborating with EMC test equipment and chamber manufacturers to provide turnkey systems and solutions to the businesses. After understanding your current requirements, we are offering best device configurations to fulfil your needs. We are delivering, installing test equipments and anechoic chambers with our partner and expert teams. When required, we are also offering on-site and remote trainings for the devices and chambers we deliver.

Our recent blog posts

ECE R10 Certification Guide is updated – Edition 1.6

On 16 December 2023, we updated our ECE R10 Certification Guide. Edition 1.6 is ready to download.How to download ECE R10 Cerfication Guide (Edition 1.6)? Click below button to visit download page of the free guide:We are offering ECE R10 related services, test...

Sample ECE R10 Certificate

Example ECE R10 certificate issued for an electronic sub assembly or component used in automotive. Check this sample certificate to understand the final delivered document showing the compliance of the product (type). ECE TYPE-APPROVAL CERTIFICATE issued by NSAI Ireland.

Location

Testups Ireland Limited is a registered company with registration number 634977. Tax ID: 3570537IH

Registered address: 22 Northumberland Road, Ballsbridge, Dublin 4. D04 ED73 Ireland