Do you want to perform Radiated Emissions tests at your own lab or in house? Do you need a radiated emissions test system or setup? We are offering CISPR 16, CISPR 25, CISPR 32, CISPR 14-1, CISPR 15 compliant Radiated Emissions Test Systems with our partner instrument manufacturers. Fulfil your radiated emissions and EMC requirements with standard compliant test systems including software. Have a standard compliant emissions test system and perform conducted emissions tests in house. We are delivering test systems to your address in 10 weeks.
Contact us and get your quote:

Radiated Emissions test is one of the EMC tests which is a common test performed for the various industries: consumer electronics, household appliances, radio devices and systems, IT equipments, machinery, medical, automotive, railway, defense and so on. The purpose is to measure unwanted RF signals emitting from the tested product or equipment under test (EUT). These signals shall be under the limits specified on the EMC standard applied. For instance, if the product is an multimedia or IT device conducted emissions testing of this product is mostly performed according to CISPR 32 or EN 55032 standard. Each product or industry is applying its own emissions test standards. In order to perform radiated emissions tests you shall have a test setup. The setup at least shall consist of three components: measuring receiver, antenna and an RF cable between the receiver and the antenna.

For full compliance radiated emissions testing, test setup requires CISPR 16-1-1 compliant EMI Receiver, CISPR 16 compliant antennas, RF or fiber cable to connect antenna and EMI Receiver, non-conductive test table (wooden or etc.), turntable (to turn the EUT), test site (OATS or anechoic chamber), pre-amplifier, pre-selector, test software. Large and medium sized manufacturers, test laboratories prefer full compliance radiated emissions test setup due to their internal quality policies or accreditation rules. If you want to apply all parameters of relevant EMC standar, you shall invest on a full-compliance test setup.

For pre-compliance testing you can choose any combination of above requirements and ignore some of them. For instance, you can use test cell instead of OATS or anechoic chamber. Pre-compliance radiated emissions tests would make your EUT’s ready for full compliance tests. Manufacturers, engineers and product developers prefer pre-compliance radiated emission test setups since it is more economic and simple. If you have already a full compliance test setup, you might invest on a pre-compliance test setup.   

Radiated emissions test systems are practical solutions for radiated emissions test setup requirement since they include a set of instruments and software:

1. EMI Receiver / EMC Analyzer (with peak, quasi-peak and average detectors)

2. Antennas (Biconical, Log-Periodic, BiLog, Combilog, Horn) 

3. Pre-amplifier (if necessary)

4. Pre-selector (if necessary)

5. RF Cable (between EMI Receiver and Antenna)

6. Test Software (to run the EMI Reciever, plot the measurement results and report)

You can have all items listed above as a system. We call such systems Radiated Emissions Test System. 

What we offer?

We are offering full compliant and pre-compliance Radiated Emissions Test Systems. Depending on your EUT (Equipment Under Test) features we are offering different configurations that fits your EMC requirements. Send us your EMC requirements and get quote for radiated emissions test systems from 9kHz up to 18 GHz. If you also need accredited calibration certificate, on-site or online training related to radiated emissions test systems, we can add these additional services to your quotation. 

Radiated Emissions Test Systems we offer are given below

Order Code Frequency

Fully-compliance (CISPR 16)

or 

Pre-compliance

Detectors Antennas Pre-amplifier Antenna Stand / Tripod Test Software Datasheet
RETS1-C 30MHz-1GHz

Pre-compliance

Peak, Quasi-Peak, Average

Biconical (25-300MHz) and

Log-Periodic (30-1GHz)

Gain: 32dB (1MHz-1GHz) (Optional, External) Included No Datasheet
RETS1-L 30MHz-1GHz Pre-compliance Peak, Quasi-Peak, Average Compact Antenna (30MHz-1GHz) Gain: 20dB (9kHz-1GHz) (Optional, External) Included

Included

(no license)

Datasheet
RETS3-P 30MHz-3GHz Fully-compliance Peak, Quasi-Peak, Average, RMS, RMS-Avarage, C-Avarage

Biconical (30-200MHz) and

Log-Periodic (200MHz-3GHz)

Gain: 20dB (Internal) Included

Included

(no license)

Datasheet
RETS6-P 30MHz-6GHz Fully-compliance Peak, Quasi-Peak, Average, RMS, RMS-Avarage, C-Avarage

Biconical (30-200MHz),

Log-Periodic (200MHz-3GHz)

and

Log-Periodic (800MHz-6GHz)

Gain: 20dB (Internal) Included

Included

(no license)

Datasheet
RETS18-P 30MHz-18GHz Fully-compliance Peak, Quasi-Peak, Average, RMS, RMS-Avarage, C-Avarage

Biconical & Log-Periodic (30MHz-6GHz)

and

Double Ridged Horn Antenna (6GHz-18GHz)

Gain: 20dB (Internal) Included

Included

(no license)

Datasheet
RETS3026-R 30MHz-26.5GHz Fully-compliance Peak, Quasi-Peak, Average, RMS

Biconical & Log-Periodic (30MHz-6GHz),

Double Ridged Horn Antenna (6GHz-18GHz),

Horn Antenna (18-40GHz)

Gain: 20dB (Internal) Included

Excluded

(optional with license)

Ask Datasheet
RETS0926-R 9kHz-26.5GHz Fully-compliance Peak, Quasi-Peak, Average, RMS

41 inch Active Monopole Antenna (9kHz-30MHz),

Biconical & Log-Periodic (30MHz-6GHz),

Double Ridged Horn Antenna (6GHz-18GHz),

Horn Antenna (18-40GHz)

Gain: 20dB (Internal) Included

Excluded

(optional with license)

Ask Datasheet

Radiated Emissions Test Systems we offer does not include any test site (Test Cell, Test Tent, OATS, Anechoic Chamber). If you want to add any of these test sites, we can add and your radiated emissions test results would be much more accurate.

Fulfil your Radiated Emissions test setup requirements

with Radiated Emissions Test Systems (fully compliant with CISPR 16)

or

with Radiated Emissions Test Systems (for pre-compliance testing)

 

We are engineers, experts and consultants specialised in electrical product testing and certification.

With our team, laboratory and partner laboratories, we are providing testing and certification services for electrical products. We are partnering with testing laboratories located in USA, Ireland, United Kingdom, Germany, Hungary, Italy, Turkey, China, Brazil and South Africa. We are providing our services worldwide.

We are also collaborating with EMC test equipment and chamber manufacturers to provide turnkey systems and solutions to the businesses. After understanding your current requirements, we are offering best device configurations to fulfil your needs. We are delivering, installing test equipments and anechoic chambers with our partner and expert teams. When required, we are also offering on-site and remote trainings for the devices and chambers we deliver.

Our recent blog posts

ECE R10 Certification Guide is updated – Edition 1.6

On 16 December 2023, we updated our ECE R10 Certification Guide. Edition 1.6 is ready to download.How to download ECE R10 Cerfication Guide (Edition 1.6)? Click below button to visit download page of the free guide:We are offering ECE R10 related services, test...

Sample ECE R10 Certificate

Example ECE R10 certificate issued for an electronic sub assembly or component used in automotive. Check this sample certificate to understand the final delivered document showing the compliance of the product (type). ECE TYPE-APPROVAL CERTIFICATE issued by NSAI Ireland.

Location

Testups Ireland Limited is a registered company with registration number 634977. Tax ID: 3570537IH

Registered address: 22 Northumberland Road, Ballsbridge, Dublin 4. D04 ED73 Ireland