RADIATED EMISSIONS TEST SYSTEMS
Do you want to perform Radiated Emissions tests at your own lab or in house? Do you need a radiated emissions test system or setup? We are offering CISPR 16, CISPR 25, CISPR 32, CISPR 14-1, CISPR 15 compliant Radiated Emissions Test Systems with our partner instrument manufacturers. Fulfil your radiated emissions and EMC requirements with standard compliant test systems including software. Have a standard compliant emissions test system and perform conducted emissions tests in house. We are delivering test systems to your address in 10 weeks.
Contact us and get your quote:
Radiated Emissions test is one of the EMC tests which is a common test performed for the various industries: consumer electronics, household appliances, radio devices and systems, IT equipments, machinery, medical, automotive, railway, defense and so on. The purpose is to measure unwanted RF signals emitting from the tested product or equipment under test (EUT). These signals shall be under the limits specified on the EMC standard applied. For instance, if the product is an multimedia or IT device conducted emissions testing of this product is mostly performed according to CISPR 32 or EN 55032 standard. Each product or industry is applying its own emissions test standards. In order to perform radiated emissions tests you shall have a test setup. The setup at least shall consist of three components: measuring receiver, antenna and an RF cable between the receiver and the antenna.
For full compliance radiated emissions testing, test setup requires CISPR 16-1-1 compliant EMI Receiver, CISPR 16 compliant antennas, RF or fiber cable to connect antenna and EMI Receiver, non-conductive test table (wooden or etc.), turntable (to turn the EUT), test site (OATS or anechoic chamber), pre-amplifier, pre-selector, test software. Large and medium sized manufacturers, test laboratories prefer full compliance radiated emissions test setup due to their internal quality policies or accreditation rules. If you want to apply all parameters of relevant EMC standar, you shall invest on a full-compliance test setup.
For pre-compliance testing you can choose any combination of above requirements and ignore some of them. For instance, you can use test cell instead of OATS or anechoic chamber. Pre-compliance radiated emissions tests would make your EUT’s ready for full compliance tests. Manufacturers, engineers and product developers prefer pre-compliance radiated emission test setups since it is more economic and simple. If you have already a full compliance test setup, you might invest on a pre-compliance test setup.
Radiated emissions test systems are practical solutions for radiated emissions test setup requirement since they include a set of instruments and software:
1. EMI Receiver / EMC Analyzer (with peak, quasi-peak and average detectors)
2. Antennas (Biconical, Log-Periodic, BiLog, Combilog, Horn)
3. Pre-amplifier (if necessary)
4. Pre-selector (if necessary)
5. RF Cable (between EMI Receiver and Antenna)
6. Test Software (to run the EMI Reciever, plot the measurement results and report)
You can have all items listed above as a system. We call such systems Radiated Emissions Test System.
What we offer?
We are offering full compliant and pre-compliance Radiated Emissions Test Systems. Depending on your EUT (Equipment Under Test) features we are offering different configurations that fits your EMC requirements. Send us your EMC requirements and get quote for radiated emissions test systems from 9kHz up to 18 GHz. If you also need accredited calibration certificate, on-site or online training related to radiated emissions test systems, we can add these additional services to your quotation.
Radiated Emissions Test Systems we offer are given below
Order Code | Frequency |
Fully-compliance (CISPR 16) or Pre-compliance |
Detectors | Antennas | Pre-amplifier | Antenna Stand / Tripod | Test Software | Datasheet |
RETS1-C | 30MHz-1GHz |
Pre-compliance |
Peak, Quasi-Peak, Average |
Biconical (25-300MHz) and Log-Periodic (30-1GHz) |
Gain: 32dB (1MHz-1GHz) (Optional, External) | Included | No | Datasheet |
RETS1-L | 30MHz-1GHz | Pre-compliance | Peak, Quasi-Peak, Average | Compact Antenna (30MHz-1GHz) | Gain: 20dB (9kHz-1GHz) (Optional, External) | Included |
Included (no license) |
Datasheet |
RETS3-P | 30MHz-3GHz | Fully-compliance | Peak, Quasi-Peak, Average, RMS, RMS-Avarage, C-Avarage |
Biconical (30-200MHz) and Log-Periodic (200MHz-3GHz) |
Gain: 20dB (Internal) | Included |
Included (no license) |
Datasheet |
RETS6-P | 30MHz-6GHz | Fully-compliance | Peak, Quasi-Peak, Average, RMS, RMS-Avarage, C-Avarage |
Biconical (30-200MHz), Log-Periodic (200MHz-3GHz) and Log-Periodic (800MHz-6GHz) |
Gain: 20dB (Internal) | Included |
Included (no license) |
Datasheet |
RETS18-P | 30MHz-18GHz | Fully-compliance | Peak, Quasi-Peak, Average, RMS, RMS-Avarage, C-Avarage |
Biconical & Log-Periodic (30MHz-6GHz) and Double Ridged Horn Antenna (6GHz-18GHz) |
Gain: 20dB (Internal) | Included |
Included (no license) |
Datasheet |
RETS3026-R | 30MHz-26.5GHz | Fully-compliance | Peak, Quasi-Peak, Average, RMS |
Biconical & Log-Periodic (30MHz-6GHz), Double Ridged Horn Antenna (6GHz-18GHz), Horn Antenna (18-40GHz) |
Gain: 20dB (Internal) | Included |
Excluded (optional with license) |
Ask Datasheet |
RETS0926-R | 9kHz-26.5GHz | Fully-compliance | Peak, Quasi-Peak, Average, RMS |
41 inch Active Monopole Antenna (9kHz-30MHz), Biconical & Log-Periodic (30MHz-6GHz), Double Ridged Horn Antenna (6GHz-18GHz), Horn Antenna (18-40GHz) |
Gain: 20dB (Internal) | Included |
Excluded (optional with license) |
Ask Datasheet |
Radiated Emissions Test Systems we offer does not include any test site (Test Cell, Test Tent, OATS, Anechoic Chamber). If you want to add any of these test sites, we can add and your radiated emissions test results would be much more accurate.
Fulfil your Radiated Emissions test setup requirements
with Radiated Emissions Test Systems (fully compliant with CISPR 16)
or
with Radiated Emissions Test Systems (for pre-compliance testing)
We are engineers, experts and consultants specialised in electrical product testing and certification.
With our team, laboratory and partner laboratories, we are providing testing and certification services for electrical products. We are partnering with testing laboratories located in USA, Ireland, United Kingdom, Germany, Hungary, Italy, Turkey, China, Brazil and South Africa. We are providing our services worldwide.
We are also collaborating with EMC test equipment and chamber manufacturers to provide turnkey systems and solutions to the businesses. After understanding your current requirements, we are offering best device configurations to fulfil your needs. We are delivering, installing test equipments and anechoic chambers with our partner and expert teams. When required, we are also offering on-site and remote trainings for the devices and chambers we deliver.
Our recent blog posts
Testups Turkiye Company Title and Address Update
With this post, we would like to announce that company title and registered address of Testups Turkiye has been changed. New company title reflects Testups brand now. Company address is in Istanbul now. Tax office is now Zincirlikuyu VD. Company information were...
YRS05 York Reference Source – 25 Hz to 6 GHz
YRS05, Noise and Comb reference noise generator, 25 Hz to 6 GHz
ISO 11452-4 Requirements
Test levels, test equipments, test setup requirements of ISO 11452-4.
Location
Testups Ireland Limited is a registered company with registration number 634977. Tax ID: 3570537IH
Registered address: 22 Northumberland Road, Ballsbridge, Dublin 4. D04 ED73 Ireland